´ó±¦ÓéÀÖ

¼æÈݹâÄ£¿é

XG-SFP-CU5MµçÀÂ

Èñ½ÝXG-SFP-CU5M SFP+µçÀÂ

0.0/5 rating (0 votes)

Specifications

  • ²úÆ·ÐͺÅ: XG-SFP-CU5M
  • ¼æÈÝÆ·ÅÆ: Èñ½ÝRuijie
  • ·â×°ÀàÐÍ: SFP+
  • ´«ÊäËÙÂÊ: 10G
  • ´«Êä¾àÀë: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ
  • ·¢É䲨³¤: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ
  • ½ÓÊÕ²¨³¤: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ
  • ÊÂÇéζÈ: ÉÌÒµ¼¶0¡æ¡«+70¡æ/¹¤Òµ¼¶-40¡æ¡«+85¡æ ¿ÉÑ¡
  • Êý×ÖÕï¶Ï: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ
  • ½ÓÊÕÁéÃô¶È: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ
  • ½ÓÊÕÁéÃô¶È: 5m ÎÞÔ´ 10.31Gbps SFP+µçÀÂ

Description

²úÆ·ÐͺţºXG-SFP-CU5M
²úÆ·ÃèÊö£ºSFP+ 10GÏßÀ 1m 10.31Gbps SFP+µçÀÂÀÂ
¼æÈÝÆ·ÅÆ£ºÈñ½ÝRuijie
Ô­³§ÃèÊö£º10G SFP+ Copper Twinax cable 1m, passive

Ä£¿éÀàÐÍ ´«Êä¾àÀë ´«Ê䲨³¤ ½Ó¿ÚÀàÐÍ ´«ÊäËÙÂÊ ÊÂÇéµçѹ Êý×ÖÕï¶Ï
SFP+ 10GÏßÀ  0~10Ã׿ÉÑ¡ Copper Copper  10G    
²úÆ·ÌØÐÔ Features: Ó¦ÓùæÄ£ Application:
SFP+ Copper Twinax cables are suitable for very short distances and offer a highly cost-effective way to connect within racks and across adjacent racks. SFP+ cables offers a low cost SFP+ solution. SFP+ directly attached twinax cable assemblies supports 10 Gigabit Ethernet, 10 Fibre Channel, and other industry standards. 

Specifications: 
¡ñ SFP+ to SFP+, 
¡ñ 7 Meters
¡ñ AWG24
¡ñ N Years Warranty

Applications:
¡ñ 1-8G Fiber Channel and 1-10G Gigabit Ethernet
¡ñ Networking, Storage, Telecommunications
¡ñ Hub, Switches, Routers, Servers, Network Interface Card(NICs)

¡ñ 10Gigabit Ethernet
¡ñ Data center cabling infrastructure
¡ñ Storage Area Networks( SAN)
Network Attached Storage 
Storage Servers 
¡ñ 1G/2G/4G/8G Fiber Channel

SFP+¹âÄ£¿éÐͺűí:

SFP+ÐͺŠ²¨³¤ DDM ¹âÏË ·¢Ë͹âÇ¿ dbm ½ÓÊÕ¹âÇ¿ dbm
(nm) (Yes/No) ÀàÐÍ ×îС ×î´ó ×îС ×î´ó
XG-SFP-SR-MM850 850 Yes ¶àÄ£ -5 -1 -7.5 0.5
XG-SFP-LR-SM1310 1310 Yes µ¥Ä£ -8.2 0.5 -10.3 0.5
XG-SFP-ER-SM1550 1550 Yes µ¥Ä£ -4.7 4 -11.3 -1
XG-SFP-ZR-SM1550 1550 Yes µ¥Ä£ 0 4 -24 -7
XS-SFP-SR 850 Yes ¶àÄ£ -5 -1 -7.5 0.5
XS-SFP-LR 1310 Yes µ¥Ä£ -8.2 0.5 -10.3 0.5

 ×¢£º

  • ¹ØÓÚ XG-SFP-ER-SM1550 ºÍ XG-SFP-ZR-SM1550 ÇëÎðʹÓö̾àÀë¹âÏËÁ¬½Ó £¬ÒÔÃâÔì³ÉÄ£¿é¹â½ÓÊÕ»ú¹ýÔØ¡£Èç¹ûÄ£ ¿é½ÓÊն˵Ĺ⹦ÂÊ´óÓÚ»ò¼´ÊÇ -1dBm £¬Ó¦¸ÃÔÚÄ£¿éµÄ½ÓÊն˼ÓÊʵ±µÄË¥¼õÆ÷ £¬Ê¹Æä½ÓÊն˵Ĺ⹦ÂÊСÓÚ-1dBm¡£
  • ¹âÄ£¿éÊôÓÚ¼¤¹â·¢ÉäÆ÷ £¬Çë×¢ÒâÓÃÑÛÄþ¾² £¬Ó¦ÖÆÖ¹Ö±ÊÓ¹âÔ´¡£
  • ΪÁ˱£»¤¹âÄ£¿éµÄÇå½à £¬ÇëÎñ±Ø°ü¹ÜÔÚδÁ¬½Ó¹âÏËÏßʱ¸ÇÉÏ·À³¾¸Ç¡£ 

SFP+Ä£¿é²¼Ïß¹æ¸ñ:

ÐͺŠ½Ó¿Ú ¹âÏË ÄÚо¹æ¸ñ ģ̬´ø¿í ×î´ó²¼Ïß¾àÀë
ÀàÐÍ ÀàÐÍ (um) (MHz¡¤km)
XG-SFP-SR-MM850 LC ¶àÄ£ 62.5 /125 200(OM1) 33m
160 26m
50/125 2000(OM3) 300m
500(OM2) 82m
400(OM1) 66m
XG-SFP-LR-SM1310 LC µ¥Ä£ 9/125 N/A 10km
XG-SFP-ER-SM1550 LC µ¥Ä£ 9/125 N/A 40km
XG-SFP-ZR-SM1550 LC µ¥Ä£ 9/125 N/A 80km
XS-SFP-SR LC ¶àÄ£ 62.5 /125 200(OM1) 33m
160 26m
50/125 2000(OM3) 300m
500(OM2) 82m
400(OM1) 66m
XS-SFP-LR LC µ¥Ä£ 9/125 N/A 10km

ÏÖÓеÄÍòÕ×SFP+Í­ÀÂÄ£¿éÐͺűí:

ÐͺÅ

Ä£¿éÀàÐÍ

Á¬½ÓÆ÷ÀàÐÍ

Í­À³¤¶È
(M)

µ¼ÌåÏß¾¶
(AWG)

Êý¾ÝËÙÂÊ
(Gb/s)

Ö§³Ö DDM
(Yes/No)

XG-SFP-CU1M

ÎÞÔ´

SFP+

1

28

10.3125

No

XG-SFP-CU3M

ÎÞÔ´

SFP+

3

28

10.3125

No

XG-SFP-CU5M

ÎÞÔ´

SFP+

5

26

10.3125

No

 

 

È«¹ú²ú»¯¹âÄ£¿é CFP2¹âÄ£¿é JYSK¹âÏËÁ¬½ÓÆ÷ ˼¿Æ¹âÄ£¿é Marconi¹âÄ£¿é Test Equipment & Others ¹âÏË·¨À¼ÊÊÅäÆ÷
SFPÈ«¹ú²ú¹âÄ£¿é CFP4¹âÄ£¿é J599IIIµçÁ¬½ÓÆ÷ ˼¿ÆFE SFP ²©´ï¹âÄ£¿é ±£Æ«¹âÆ÷¼þ ¹âÏËÌøÏß&βÏË
1x9È«¹ú²ú¹âÄ£¿é CFP8 400Gbps S6¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆSFP+¹âÄ£¿é Íø¼þ¹âÄ£¿é In-line Depolarizer FTTAÀ­Ô¶»ùÕ¾¹âÏËÌøÏß
ÌØÖÖ¹âÄ£¿é CDFP 400Gbps S7¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆXFP¹âÄ£¿é Nortel¹âÄ£¿é In-line Polarizer MPO/MTP¸ßÃܶÈϵÁÐ
25G~400G¸ßËÙ¹âÄ£¿é MicroQSFP¹âÄ£¿é GYM¹âÏËÁ¬½ÓÆ÷ ˼¿ÆCFP¹âÄ£¿é Moxa¹âÄ£¿é IPBC/S ¾üÓÃÒ°Õ½·ÀË®¹âÏËÌøÏß
200km³¬³¤¾à¹âÄ£¿é DSFP¹âÄ£¿é J599III¹âÏËÁ¬½ÓÆ÷ ˼¿ÆQSFP-DD ¹âÄ£¿é º£¿µÍþÊÓHIKVISION¹âÄ£¿é PBC/S ÌØÖÖ¹âÏ˹âÀÂ
5GÒƶ¯Í¨ÐŹâÄ£¿é FT-61¹âÄ£¿é Ë®ÃܹâÀÂÁ¬½ÓÆ÷ ˼¿ÆQSFP+¹âÄ£¿é McAfee¹âÄ£¿é PM BPF ÌØÖÖÏßÀÂ×é¼þ
SFP¹âÄ£¿é OLT¹âÄ£¿é ¹âÏËÁ¬½ÓÆ÷ת½ÓÆ÷ ˼¿ÆGE SFP SMCÖÇ°î¹âÄ£¿é PM Circulator ͨÓùâÀ¹âÏËÌøÏß
1.25G SFP ONU¹âÄ£¿é FT-A4ϵÁÐÁ¬½ÓÆ÷ ˼¿ÆSFP OC3 °²»ª¸ßAvago¹âÄ£¿é PM Collimator MXC? ¶àо¹âÀÂ×é¼þ
CWDM SFP PLCC¹âÄ£¿é USB¹âÏËÑÓ³¤Ïß Ë¼¿ÆSFP OC12 °²»ª¸ßAvago 1x9¹âÄ£¿é PM Coupler PRIZM? LIGHTTURN?×é¼þ
DWDM SFP RJ¹âÄ£¿é HDMI ˼¿ÆSFP OC48 °²»ª¸ßAvago SFF¹âÄ£¿é PM CWDM ¹âÏË»úÏä
BIDI-SFP SFF¹âÄ£¿é ÌØÖÖµçÁ¬½ÓÆ÷ ˼¿ÆGBIC¹âÄ£¿é °²»ª¸ßAvago SFP¹âÄ£¿é PM DWDM SMA-ÌØÊâÏËоϵÁÐ
SGMII SFP SNAP12¹âÄ£¿é Ô²ÐÎÁ¬½ÓÆ÷ ˼¿ÆX2¹âÄ£¿é °²»ª¸ßAvago QSFP28 ¹âÄ£¿é PM Faraday mirror ÌØÊâ½ÓͷϵÁÐ
Video SFP¹âÄ£¿é USOT¹âÄ£¿é ¾ØÐεçÁ¬½ÓÆ÷ ˼¿ÆXENPAK¹âÄ£¿é °²»ª¸ßAvago QSFP+¹âÄ£¿é PM Fiber mirror îøװϵÁÐ
Copper SFP X2¹âÄ£¿é ÌØÖÖ¹âÏ˹âÀ »ªÈý¹âÄ£¿é °²»ª¸ßAvago SNAP12¹âÄ£¿é PM Filter Coupler ¹âñîºÏÆ÷Coupler
µÍ¹¦ºÄSFP Xenpak¹âÄ£¿é ÌØÖÖ¹âÏË »ªÈýSFP °²»ª¸ßAvago ÆäËû¹âÄ£¿é PM Fused Coupler ƤÏËÌøÏßϵÁÐ
SFP+¹âÄ£¿é ¹âµç±àÂëÆ÷Ä£¿é ¹âÏËÆ÷¼þ »ªÈýSFP+ °²»ª¸ß Embedded¹âÄ£¿é PM FWDM ´óоÊýϵÁÐ
CWDM SFP+ ¹âÄ£¿é²âÊÔ°å ÌØÖÖ¹âÀ¼°¹âÀÂ×é¼þ »ªÈýSFP28 ¹âÄ£¿é °²»ª¸ßFiber Optics¹âÄ£¿é PM Isolator »Ø·ÌøÏßϵÁÐ
DWDM SFP+ ¹âÄ£¿éÁý×Ó×ù×Ó ¹âź »ªÈýQSFP+¹âÄ£¿é Industrial Transmitters and Receivers PM Isolator WDM ±£Æ«¹âÏËϵÁÐ
BIDI SFP+ DAC ¸ßËÙÏßÀ ±ê×¼¹âñî »ªÈýQSFP28 ¹âÄ£¿é Optical Transceivers PM PLC ¹âͨÐÅ×é¼þ
Tunable SFP+ ¹âÏË»¬»·|¹âµç»¬»· SMA²âÊÔÏßÀ »ªÈý CFP¹âÄ£¿é ·Éͨ¹âÄ£¿é PM Tap Isolator ¹â¸ôÀëÆ÷isolator
16GFC SFP+ ¹âÀ³µ OSA »ªÈý CXP¹âÄ£¿é Finisar¹âÄ£¿é PM Tap Isolator WDM ÆäËü¹âÆ÷¼þ
25GE SFP+ ¾üÆ·¼¶DIN¹âÄ£¿é PON BOSA »ªÈý CX4¸ßËÙµçÀ ·ÆÄáÈøFinisar SFF¹âÄ£¿é PM VOA ¿Éµ÷Â˲¨Æ÷
32GFC SFP+ ËÜÁϹâÏËÄ£¿é Pigtailed PD »ªÈýXFP yellobrik SDI¹âÄ£¿é ÆäËü±£Æ«Æ÷¼þ ¿Éµ÷Ë¥¼õÆ÷
SFP28¹âÄ£¿é Ìæ»»°²»ª¸ß¹¤ÒµµçÁ¦¹âÄ£¿é RFoG BOSA »ªÈýGE SFP ÂÞ¿ËΤ¶ûAB¹âÄ£¿é ¹â·Ö·Æ÷ À­×¶ñîºÏÆ÷
SFP56¹âÄ£¿é ¼æÈݹú²ú»¯Ìæ»»°²»ª¸ß¹âñî TO-CAN »ªÈýFE SFP Â޽ܿµ¹âÄ£¿é FBTÀ­×¶·Ö·Æ÷ ÎÞÔ´¹âÆ÷¼þ
SFP-DD¹âÄ£¿é ÉäƵ¹âÄ£¿é ¹âÏËζȴ«¸ÐÆ÷ »ªÈýSFP STM-4 ÑлªAdvantech¹âÄ£¿é PLC ¹â·Ö·Æ÷ ·¨À­µÚÐýת¾µ
QSFP¹âÄ£¿é ΢ÐͶà·¹âÄ£¿é ¹âÏËÓ¦±ä´«¸ÐÆ÷ »ªÈýSFP STM-16 È«¹ú²ú»¯¹âÆ÷¼þ PLCƽÃ沨µ¼¹â·Ö·Æ÷ ²¨·Ö¸´ÓÃÆ÷
QSFP+ ¹âÄ£¿é ÌØÖÖ¹âÄ£¿é ¹âÏ˼ÓËٶȴ«¸ÐÆ÷ »ªÈýGBIC¹âÄ£¿é FT-XSϵÁР¹ú²ú»¯°ëµ¼Ìå¹â·Å´óÆ÷ ¹â¿ª¹Ø AWG DWDM²¨·Ö¸´ÓÃÆ÷
QSFP28¹âÄ£¿é HPC²¢ÐйâÄ£¿é ¹âÏßѹÁ¦´«¸ÐÆ÷ »ªÈýBIDI¹âÄ£¿é ¹âÏËÕóÁÐϵÁР̽²âÆ÷ Fused WDM²¨·Ö¸´ÓÃÆ÷
QSFP56¹âÄ£¿é LC-RJ³¬Ð¡Ð͵¥Â·¹âÄ£¿é ¹âÏËλÒÆ´«¸ÐÆ÷ »ªÈýXENPAK¹âÄ£¿é ¸ßËÙÄ£¿é΢Á¬½Ó ¹â¹¦ÂÊ¼Æ FWDM²¨·Ö¸´ÓÃÆ÷
QSFP112 400G¹âÄ£¿é LCC48¹âÄ£¿é ¹âÏËÓ¦Á¦´«¸ÐÆ÷ »ªÈýEPON OLT SFP Ïà¸ÉͨѶ¹âÁ¬½Ó È«¹âÏËÏàλÀ­ÉìÆ÷ Mini΢ÐÍ´Ö²¨·Ö¸´ÓÃÆ÷
QSFP224¹âÄ£¿é LC³¬¶ÌÐ͹âÄ£¿é ¹âÏË´«¸ÐÆÊÎöÒÇ Öк½¹âµç¹âÄ£¿é ¹è¹â×ÓÆ÷¼þ¹âÁ´½Ó ¹âÏË×¼Ö±Æ÷ ¹â·Ö²å¸´ÓÃÆ÷
QSFP-DD¹âÄ£¿é SNAP12¹âÄ£¿é ¹âÏËÂþÑÜʽ²âÎÂÖ÷»ú ÖÐÐ˹âÄ£¿é Bio-Medical Equipment ¹âË¥¼õÆ÷ϵÁÐ ÆäËüÖÖÀನ·Ö¸´ÓÃÆ÷²úƷϵÁÐ
QSFP-DD800¹âÄ£¿é ΢Ð͹âÄ£¿é ¹âÏ˲¼ÀïÔ¨ÐźŽâµ÷ÒÇ Èñ½Ý¹âÄ£¿é Components for Fiber Laser ¹âÆ«Õñ¿ØÖÆÆ÷ Ãܼ¯²¨·Ö¸´ÓÃÆ÷
OSFP 400Gbps ΢ÐͿɲå°ÎBGA¹âÄ£¿é ÂþÑÜʽ¹âÏËÉùÕñÐźŽâµ÷ÒÇ »ÝÆÕ¹âÄ£¿é Components for Fiber sensing ¹âÔ´ ´Ö²¨·Ö¸´ÓÃÆ÷
OSFP 800G¹âÄ£¿é ±íÌùʽµ¥Â·¹âÄ£¿é Camera Link ÉñÖÝÊýÂë¹âÄ£¿é Components for Optical Network ¹â»·ÐÐÆ÷Circulator WDMÄ£¿é
OSFP 1.6T¹âÄ£¿é ÌØÖÖ¹âÏËÁ¬½ÓÆ÷ ¹âÄ£¿é֪ʶ Juniper¹âÄ£¿é EDFA¹âÏË·Å´óÆ÷ ¹âÏËÑÓ³ÙÏß Â˲¨Æ÷
HSFP 1.6T~12.8T¹âÄ£¿é J599¹âÏ˲åÍ·²å×ù »ªÎª¹âÄ£¿é Extreme¹âÄ£¿é ¹âÏË´«¸ÐÆ÷ É«É¢Å⳥ģ¿é µûÐμ¤¹âÆ÷
XFP¹âÄ£¿é ODC¹âÏËÁ¬½ÓÆ÷ϵÁÐ »ªÎªGE SFP Brocade¹âÄ£¿é High power Component ¹âÏË·Å´óÆ÷ ¹âñîºÏÆ÷&·Ö·Æ÷
CWDM XFP ÆäËûÌØÖÖ¹âÏËÁ¬½ÓÆ÷ »ªÎªQSFP+¹âÄ£¿é D-Link¹âÄ£¿é HP In-line Polarizer ÎÞÔ´´«Êäת»»Æ÷ ¹âÏË»·ÐÎÆ÷&·¨À­µÚÐýת¾µ
DWDM XFP Ò°Õ½¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP+ ºÕ˼Âü¹âÄ£¿é HP Isolator ¹âÏ˼¤¹âÆ÷ ¹âÏ˸ôÀëÆ÷&²¨·Ö¸´ÓÃÆ÷
BIDI XFP ÌØÖÖ¹âµçÁ¬½ÓÆ÷ »ªÎªQSFP28 °¢¶û¿¨ÌØÀÊѶ¹âÄ£¿é HP PBC/S ¹âµ÷ÖÆÆ÷ ¹âÏË·ÖÊøÆ÷&ºÏÊøÆ÷£¨PBS/PBC£©
1x9¹âÄ£¿é J599IIIÆéá«Æµ»ì×°Á¬½ÓÆ÷ »ªÎªFE SFP Allied Telesis¹âÄ£¿é Pump Combiner ¹âµç̽²âÆ÷ ¹âÏ˹âÕ¤
CSFP¹âÄ£¿é NGC¹âÏËÁ¬½ÓÆ÷ »ªÎªXFP Foundry¹âÄ£¿é HP Circulator ¹âÏËÆ«Õñ ¸ßËÙÏßÀÂ
CSFP+10G¹âÄ£¿é J599A6¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP OC12 Force10¹âÄ£¿é Pump laser protector ¹âÏËÂ˲¨Æ÷
CXP¹âÄ£¿é GYMB¹âÏËÁ¬½ÓÆ÷ »ªÎªGBIC¹âÄ£¿é Blade¹âÄ£¿é Hybrid for EDFA ͬÖἤ¹âÆ÷
CFP¹âÄ£¿é J599III¹âµçÁ¬½ÓÆ÷ »ªÎªSFP STM16 Linksys¹âÄ£¿é Test Equipment & Others ͬÖáµçÀÂ

028-85255257 | sales@f-tone.com

±ê׼ЭÒé¹âÄ£¿é²úÆ·

¼æÈÝЭÒé¹âÄ£¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

¼¼ÊõÖ§³Ö

ÍøÕ¾µØͼ
ÓÑÇéÁ´½Ó£º8868ÌåÓý¹Ù·½Èë¿Ú  yl6809ÓÀÀû  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  °ÙÀÖ²©  Àû°Äƽ̨ע²á¿ª»§  Ì¸Çò°ÉÌåÓýappÏÂÔØ  ×ðÁú¿­Ê±  918²©ÌìÌà 918²©ÌìÌà ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz©  pgÃâ·ÑÓÎÏ·ÊÔÍæÍøÒ³°æ  mg²»ÐàÇéÔµ  ÌÚ²©»á¹ÙÍø  ×ðÁú¿­Ê±¹ÙÍø  welcomeÓ¯²Ê¹º²Ê´óÌü