´ó±¦ÓéÀÖ

GLC-ZX-SM

GLC-ZX-SM

0.0/5 rating (0 votes)

Specifications

  • ²úÆ·ÐͺÅ: GLC-ZX-SM
  • ¼æÈÝÆ·ÅÆ: ˼¿ÆCisco
  • ·â×°ÀàÐÍ: SFP
  • ´«ÊäËÙÂÊ: 1.25Gb/s,GE,1000Base-T,OC24
  • ´«Êä¾àÀë: µ¥Ä£80¹«Àï
  • ·¢É䲨³¤: 1550nm
  • ½ÓÊÕ²¨³¤: 1550nm
  • ÊÂÇéζÈ: ÉÌÒµ¼¶0¡æ¡«+70¡æ/¹¤Òµ¼¶-40¡æ¡«+85¡æ ¿ÉÑ¡
  • Êý×ÖÕï¶Ï: ´øDDM/²»´øDDM ¿ÉÑ¡
  • ½ÓÊÕÁéÃô¶È: µ¥Ä£80¹«Àï
  • ½ÓÊÕÁéÃô¶È: µ¥Ä£80¹«Àï

Description

²úÆ·Ðͺţº(CISCO:GLC-ZX-SM)
²úÆ·ÃèÊö£ºSFP,1000Base-ZXǧÕ×¹âÄ £¿é,1550ÄÉÃ×,µ¥Ä£80¹«Àï
¼æÈÝÆ·ÅÆ£ºCISCO
Ô­³§ÃèÊö£ºSFP,1.25Gb/s,GE,1000Base-ZX,SMF,1550nm,80KM

Ä £¿éÀàÐÍ ´«Êä¾àÀë ´«Ê䲨³¤ ½Ó¿ÚÀàÐÍ ´«ÊäËÙÂÊ ÊÂÇéµçѹ Êý×ÖÕï¶Ï
SFP 80KM 1550 nm Ë«LC½Ó¿Ú 1.25G b/s 3.3V ¿ÉÑ¡
²úÆ·ÌØÐÔ Features: Ó¦ÓùæÄ£ Application:
×î´ó´«ÊäËÙÂÊ1.25Gbps
1550ÄÉÃ× DFB¼¤¹âÆ÷
µä·¶´«Êä¾àÀë80¹«Àï(µ¥Ä£¹âÏË)
3.3Vµ¥µçѹ£¬TTLÂß¼­½Ó¿Ú
Ë«LC½Ó¿Ú£¬Ö§³ÖÈȲå°Î
1À༤¹âÆ÷
Ö§³ÖÊý×ÖÕï¶Ï¹¦Ð§
ÇкÏMSA SFP¹æ·¶
ÇкÏSFF-8472¹æ·¶
ÇÐºÏ IEC60825-1±ê×¼
ÊÂÇéÇé¿öζÈ: 0¡æ to +70¡æ
ǧÕ×ÒÔÌ«Íø½»»»»ú
¹âÏËͨµÀ½»»»»ú
ÆäËû¹âÏËÍøÂç

¼æÈÝ˼¿ÆGLC-ZX-SM SFPǧÕ×ZX¹âÄ £¿é£¬Îȶ¨¿É¿¿£¬»ù±¾ÃèÊö£ºSFP·â×°£¬1000BASE-ZX¹âÄ £¿é£¬1550ÄÉÃ×£¬µ¥Ä£80¡«100¹«ÀDDMÊý×ÖÕï¶Ï.

¸Ã²úÆ·Ö§³Ö1.25G´«ÊäËÙÂÊ£¬1550nmÖÐÐIJ¨³¤£¨½ÓÄÉDFB¼¤¹âÆ÷¼þ£©£¬¿ÉÖ§³Ö×î´ó´«Êä¾àÀë100km(µ¥Ä£¹âÏË´«Êä½éÖÊ£º9/125um SMF)¡£Ö§³ÖÈȲå°Î£¬Ë«ÏËË«Ïò´«Ê䣬֧³ÖζȹæÄ££¨-40¡æ~+85¡æ£©£¬Ë«LC½Ó¿Ú£¬ÊÂÇéµçѹ3.3·ü¡£Ö÷ÒªÓ¦ ÓÃÔÚ1000BASE-ZX EthernetǧÕ×ÒÔÌ«ÍøµÈÁìÓò¡£

F-tone ¶Ô¼æÈÝ˼¿Æ¹âÄ £¿éµÄÑб¬·¢²ú£¬ÓÐ×ÅÍêÉƳÉÊìµÄ¼¼Êõ£¬°ü¹ÜÁËF-tone¹âÄ £¿éºÜºÃµÄ¼æÈÝÓ¦ÓÃÓÚ˼¿ÆÏàÓ¦µÄÉ豸ÉÏ£¨½»»»»ú£¬Â·ÓÉÆ÷µÈ£©¡£¸Ã¿î²úƷͬÐÐÖÐÓÐ׿«¸ßµÄÐԼ۱ȣ¬Í¬Ê±¶¼¾ßÓÐCE£¬FCC£¬ROSHµÈ¹ú¼ÊÈÏÖ¤¡£

ÒÔÏÂÊǼæÈÝ˼¿ÆGLC-ZX-SM¹âÄ £¿é¹æ¸ñ²ÎÊý:

GLC-ZX-SM CISCO compatible

KEY FEATURES APPLICATION
Up to 2.125Gb/s 1.25Gb/s 1000BASE-ZX Ethernet
Hot-pluggable SFP  
1550nm DFB  
Duplex LC  
80km~100km on 9/125um SMF  
-40C to 85C  
3.3V,Power Consumption <1W  
DDM/DOM  
SPECIFICATIONS
Form Factor SFP
Distance 80km~100km SMF
Protocol 1.25Gb/s 1000BASE-ZX Ethernet
Data Rate(max) 2.125Gb/s
Low End Case Temperature(¡ãC) -40¡ãC
High End Case Temperature(¡ãC) 85¡ãC
Diagnostics DDM/DOM
Transmitter & Power Out DFB,Pout 0~5dB
Receiver & Sense PIN,Pin >-23dBm
Voltage Supply 3.3
Connector LC Dulplex
RoHS YES
Certification CE FCC

Êý×ÖÕï¶Ï£¬ÓÖ³ÆDD¡¢DOM¡¢DDMI£¬¾ÍÊÇÄ £¿é¿ÉÒÔÏòÖ÷»úʵʱµÄÌṩÄ £¿éÄÚ²¿µÄÊÂÇé״̬ÐÅÏ¢£¬°üÀ¨£ºµçѹ¡¢Î¶ȡ¢·¢Éä¹â¹¦ÂÊ¡¢½ÓÊչ⹦ÂÊ¡¢¼¤¹âÆ÷µÄÆ«ÖõçÁ÷ £»2003ÄêÇ°µÄ´ó²¿·Ö²úÆ·£¬¶¼Ã»ÓÐDOMµÄ¹¦Ð§

Ô­×°¹Ù·½GLC-ZX-SMÃèÊö£º£¨1000BASE-ZX±ê×¼¹âÄ £¿é£¬ÔÚ±ê×¼µ¥Ä£¹âÏ˽éÖÊÉÏ´«Êä¿É´ï70¹«Àï¾àÀ룩

1000BASE-ZX SFP for Long-Reach Single-Mode Fibers

The 1000BASE-ZX SFP operates on standard single-mode fiber-optic link spans of up to approximately 70 km in length. The SFP provides an optical link budget of 21 dB, but the precise link span length depends on multiple factors such as fiber quality, number of splices, and connectors.
When shorter distances of single-mode fiber (SMF) are used, it might be necessary to insert an inline optical attenuator in the link to avoid overloading the receiver. A 10-dB inline optical attenuator should be inserted between the fiber-optic cable plant and the receiving port on the SFP at each end of the link whenever the fiber-optic cable span loss is less than 8 dB.
È«¹ú²ú»¯¹âÄ £¿é CFP2¹âÄ £¿é JYSK¹âÏËÁ¬½ÓÆ÷ ˼¿Æ¹âÄ £¿é Marconi¹âÄ £¿é Test Equipment & Others ¹âÏË·¨À¼ÊÊÅäÆ÷
SFPÈ«¹ú²ú¹âÄ £¿é CFP4¹âÄ £¿é J599IIIµçÁ¬½ÓÆ÷ ˼¿ÆFE SFP ²©´ï¹âÄ £¿é ±£Æ«¹âÆ÷¼þ ¹âÏËÌøÏß&βÏË
1x9È«¹ú²ú¹âÄ £¿é CFP8 400Gbps S6¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆSFP+¹âÄ £¿é Íø¼þ¹âÄ £¿é In-line Depolarizer FTTAÀ­Ô¶»ùÕ¾¹âÏËÌøÏß
ÌØÖÖ¹âÄ £¿é CDFP 400Gbps S7¾ØÐÎÁ¬½ÓÆ÷ ˼¿ÆXFP¹âÄ £¿é Nortel¹âÄ £¿é In-line Polarizer MPO/MTP¸ßÃܶÈϵÁÐ
25G~400G¸ßËÙ¹âÄ £¿é MicroQSFP¹âÄ £¿é GYM¹âÏËÁ¬½ÓÆ÷ ˼¿ÆCFP¹âÄ £¿é Moxa¹âÄ £¿é IPBC/S ¾üÓÃÒ°Õ½·ÀË®¹âÏËÌøÏß
200km³¬³¤¾à¹âÄ £¿é DSFP¹âÄ £¿é J599III¹âÏËÁ¬½ÓÆ÷ ˼¿ÆQSFP-DD ¹âÄ £¿é º £¿µÍþÊÓHIKVISION¹âÄ £¿é PBC/S ÌØÖÖ¹âÏ˹âÀÂ
5GÒƶ¯Í¨ÐŹâÄ £¿é FT-61¹âÄ £¿é Ë®ÃܹâÀÂÁ¬½ÓÆ÷ ˼¿ÆQSFP+¹âÄ £¿é McAfee¹âÄ £¿é PM BPF ÌØÖÖÏßÀÂ×é¼þ
SFP¹âÄ £¿é OLT¹âÄ £¿é ¹âÏËÁ¬½ÓÆ÷ת½ÓÆ÷ ˼¿ÆGE SFP SMCÖÇ°î¹âÄ £¿é PM Circulator ͨÓùâÀ¹âÏËÌøÏß
1.25G SFP ONU¹âÄ £¿é FT-A4ϵÁÐÁ¬½ÓÆ÷ ˼¿ÆSFP OC3 °²»ª¸ßAvago¹âÄ £¿é PM Collimator MXC? ¶àо¹âÀÂ×é¼þ
CWDM SFP PLCC¹âÄ £¿é USB¹âÏËÑÓ³¤Ïß Ë¼¿ÆSFP OC12 °²»ª¸ßAvago 1x9¹âÄ £¿é PM Coupler PRIZM? LIGHTTURN?×é¼þ
DWDM SFP RJ¹âÄ £¿é HDMI ˼¿ÆSFP OC48 °²»ª¸ßAvago SFF¹âÄ £¿é PM CWDM ¹âÏË»úÏä
BIDI-SFP SFF¹âÄ £¿é ÌØÖÖµçÁ¬½ÓÆ÷ ˼¿ÆGBIC¹âÄ £¿é °²»ª¸ßAvago SFP¹âÄ £¿é PM DWDM SMA-ÌØÊâÏËоϵÁÐ
SGMII SFP SNAP12¹âÄ £¿é Ô²ÐÎÁ¬½ÓÆ÷ ˼¿ÆX2¹âÄ £¿é °²»ª¸ßAvago QSFP28 ¹âÄ £¿é PM Faraday mirror ÌØÊâ½ÓͷϵÁÐ
Video SFP¹âÄ £¿é USOT¹âÄ £¿é ¾ØÐεçÁ¬½ÓÆ÷ ˼¿ÆXENPAK¹âÄ £¿é °²»ª¸ßAvago QSFP+¹âÄ £¿é PM Fiber mirror îøװϵÁÐ
Copper SFP X2¹âÄ £¿é ÌØÖÖ¹âÏ˹âÀ »ªÈý¹âÄ £¿é °²»ª¸ßAvago SNAP12¹âÄ £¿é PM Filter Coupler ¹âñîºÏÆ÷Coupler
µÍ¹¦ºÄSFP Xenpak¹âÄ £¿é ÌØÖÖ¹âÏË »ªÈýSFP °²»ª¸ßAvago ÆäËû¹âÄ £¿é PM Fused Coupler ƤÏËÌøÏßϵÁÐ
SFP+¹âÄ £¿é ¹âµç±àÂëÆ÷Ä £¿é ¹âÏËÆ÷¼þ »ªÈýSFP+ °²»ª¸ß Embedded¹âÄ £¿é PM FWDM ´óоÊýϵÁÐ
CWDM SFP+ ¹âÄ £¿é²âÊÔ°å ÌØÖÖ¹âÀ¼°¹âÀÂ×é¼þ »ªÈýSFP28 ¹âÄ £¿é °²»ª¸ßFiber Optics¹âÄ £¿é PM Isolator »Ø·ÌøÏßϵÁÐ
DWDM SFP+ ¹âÄ £¿éÁý×Ó×ù×Ó ¹âź »ªÈýQSFP+¹âÄ £¿é Industrial Transmitters and Receivers PM Isolator WDM ±£Æ«¹âÏËϵÁÐ
BIDI SFP+ DAC ¸ßËÙÏßÀ ±ê×¼¹âñî »ªÈýQSFP28 ¹âÄ £¿é Optical Transceivers PM PLC ¹âͨÐÅ×é¼þ
Tunable SFP+ ¹âÏË»¬»·|¹âµç»¬»· SMA²âÊÔÏßÀ »ªÈý CFP¹âÄ £¿é ·Éͨ¹âÄ £¿é PM Tap Isolator ¹â¸ôÀëÆ÷isolator
16GFC SFP+ ¹âÀ³µ OSA »ªÈý CXP¹âÄ £¿é Finisar¹âÄ £¿é PM Tap Isolator WDM ÆäËü¹âÆ÷¼þ
25GE SFP+ ¾üÆ·¼¶DIN¹âÄ £¿é PON BOSA »ªÈý CX4¸ßËÙµçÀ ·ÆÄáÈøFinisar SFF¹âÄ £¿é PM VOA ¿Éµ÷Â˲¨Æ÷
32GFC SFP+ ËÜÁϹâÏËÄ £¿é Pigtailed PD »ªÈýXFP yellobrik SDI¹âÄ £¿é ÆäËü±£Æ«Æ÷¼þ ¿Éµ÷Ë¥¼õÆ÷
SFP28¹âÄ £¿é Ìæ»»°²»ª¸ß¹¤ÒµµçÁ¦¹âÄ £¿é RFoG BOSA »ªÈýGE SFP ÂÞ¿ËΤ¶ûAB¹âÄ £¿é ¹â·Ö·Æ÷ À­×¶ñîºÏÆ÷
SFP56¹âÄ £¿é ¼æÈݹú²ú»¯Ìæ»»°²»ª¸ß¹âñî TO-CAN »ªÈýFE SFP Â޽ܿµ¹âÄ £¿é FBTÀ­×¶·Ö·Æ÷ ÎÞÔ´¹âÆ÷¼þ
SFP-DD¹âÄ £¿é ÉäƵ¹âÄ £¿é ¹âÏËζȴ«¸ÐÆ÷ »ªÈýSFP STM-4 ÑлªAdvantech¹âÄ £¿é PLC ¹â·Ö·Æ÷ ·¨À­µÚÐýת¾µ
QSFP¹âÄ £¿é ΢ÐͶà·¹âÄ £¿é ¹âÏËÓ¦±ä´«¸ÐÆ÷ »ªÈýSFP STM-16 È«¹ú²ú»¯¹âÆ÷¼þ PLCƽÃ沨µ¼¹â·Ö·Æ÷ ²¨·Ö¸´ÓÃÆ÷
QSFP+ ¹âÄ £¿é ÌØÖÖ¹âÄ £¿é ¹âÏ˼ÓËٶȴ«¸ÐÆ÷ »ªÈýGBIC¹âÄ £¿é FT-XSϵÁР¹ú²ú»¯°ëµ¼Ìå¹â·Å´óÆ÷ ¹â¿ª¹Ø AWG DWDM²¨·Ö¸´ÓÃÆ÷
QSFP28¹âÄ £¿é HPC²¢ÐйâÄ £¿é ¹âÏßѹÁ¦´«¸ÐÆ÷ »ªÈýBIDI¹âÄ £¿é ¹âÏËÕóÁÐϵÁР̽²âÆ÷ Fused WDM²¨·Ö¸´ÓÃÆ÷
QSFP56¹âÄ £¿é LC-RJ³¬Ð¡Ð͵¥Â·¹âÄ £¿é ¹âÏËλÒÆ´«¸ÐÆ÷ »ªÈýXENPAK¹âÄ £¿é ¸ßËÙÄ £¿é΢Á¬½Ó ¹â¹¦ÂÊ¼Æ FWDM²¨·Ö¸´ÓÃÆ÷
QSFP112 400G¹âÄ £¿é LCC48¹âÄ £¿é ¹âÏËÓ¦Á¦´«¸ÐÆ÷ »ªÈýEPON OLT SFP Ïà¸ÉͨѶ¹âÁ¬½Ó È«¹âÏËÏàλÀ­ÉìÆ÷ Mini΢ÐÍ´Ö²¨·Ö¸´ÓÃÆ÷
QSFP224¹âÄ £¿é LC³¬¶ÌÐ͹âÄ £¿é ¹âÏË´«¸ÐÆÊÎöÒÇ Öк½¹âµç¹âÄ £¿é ¹è¹â×ÓÆ÷¼þ¹âÁ´½Ó ¹âÏË×¼Ö±Æ÷ ¹â·Ö²å¸´ÓÃÆ÷
QSFP-DD¹âÄ £¿é SNAP12¹âÄ £¿é ¹âÏËÂþÑÜʽ²âÎÂÖ÷»ú ÖÐÐ˹âÄ £¿é Bio-Medical Equipment ¹âË¥¼õÆ÷ϵÁÐ ÆäËüÖÖÀನ·Ö¸´ÓÃÆ÷²úƷϵÁÐ
QSFP-DD800¹âÄ £¿é ΢Ð͹âÄ £¿é ¹âÏ˲¼ÀïÔ¨ÐźŽâµ÷ÒÇ Èñ½Ý¹âÄ £¿é Components for Fiber Laser ¹âÆ«Õñ¿ØÖÆÆ÷ Ãܼ¯²¨·Ö¸´ÓÃÆ÷
OSFP 400Gbps ΢ÐͿɲå°ÎBGA¹âÄ £¿é ÂþÑÜʽ¹âÏËÉùÕñÐźŽâµ÷ÒÇ »ÝÆÕ¹âÄ £¿é Components for Fiber sensing ¹âÔ´ ´Ö²¨·Ö¸´ÓÃÆ÷
OSFP 800G¹âÄ £¿é ±íÌùʽµ¥Â·¹âÄ £¿é Camera Link ÉñÖÝÊýÂë¹âÄ £¿é Components for Optical Network ¹â»·ÐÐÆ÷Circulator WDMÄ £¿é
OSFP 1.6T¹âÄ £¿é ÌØÖÖ¹âÏËÁ¬½ÓÆ÷ ¹âÄ £¿é֪ʶ Juniper¹âÄ £¿é EDFA¹âÏË·Å´óÆ÷ ¹âÏËÑÓ³ÙÏß Â˲¨Æ÷
HSFP 1.6T~12.8T¹âÄ £¿é J599¹âÏ˲åÍ·²å×ù »ªÎª¹âÄ £¿é Extreme¹âÄ £¿é ¹âÏË´«¸ÐÆ÷ É«É¢Åâ³¥Ä £¿é µûÐμ¤¹âÆ÷
XFP¹âÄ £¿é ODC¹âÏËÁ¬½ÓÆ÷ϵÁÐ »ªÎªGE SFP Brocade¹âÄ £¿é High power Component ¹âÏË·Å´óÆ÷ ¹âñîºÏÆ÷&·Ö·Æ÷
CWDM XFP ÆäËûÌØÖÖ¹âÏËÁ¬½ÓÆ÷ »ªÎªQSFP+¹âÄ £¿é D-Link¹âÄ £¿é HP In-line Polarizer ÎÞÔ´´«Êäת»»Æ÷ ¹âÏË»·ÐÎÆ÷&·¨À­µÚÐýת¾µ
DWDM XFP Ò°Õ½¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP+ ºÕ˼Âü¹âÄ £¿é HP Isolator ¹âÏ˼¤¹âÆ÷ ¹âÏ˸ôÀëÆ÷&²¨·Ö¸´ÓÃÆ÷
BIDI XFP ÌØÖÖ¹âµçÁ¬½ÓÆ÷ »ªÎªQSFP28 °¢¶û¿¨ÌØÀÊѶ¹âÄ £¿é HP PBC/S ¹âµ÷ÖÆÆ÷ ¹âÏË·ÖÊøÆ÷&ºÏÊøÆ÷£¨PBS/PBC£©
1x9¹âÄ £¿é J599IIIÆéá«Æµ»ì×°Á¬½ÓÆ÷ »ªÎªFE SFP Allied Telesis¹âÄ £¿é Pump Combiner ¹âµç̽²âÆ÷ ¹âÏ˹âÕ¤
CSFP¹âÄ £¿é NGC¹âÏËÁ¬½ÓÆ÷ »ªÎªXFP Foundry¹âÄ £¿é HP Circulator ¹âÏËÆ«Õñ ¸ßËÙÏßÀÂ
CSFP+10G¹âÄ £¿é J599A6¹âÏËÁ¬½ÓÆ÷ »ªÎªSFP OC12 Force10¹âÄ £¿é Pump laser protector ¹âÏËÂ˲¨Æ÷
CXP¹âÄ £¿é GYMB¹âÏËÁ¬½ÓÆ÷ »ªÎªGBIC¹âÄ £¿é Blade¹âÄ £¿é Hybrid for EDFA ͬÖἤ¹âÆ÷
CFP¹âÄ £¿é J599III¹âµçÁ¬½ÓÆ÷ »ªÎªSFP STM16 Linksys¹âÄ £¿é Test Equipment & Others ͬÖáµçÀÂ

028-85255257 | sales@f-tone.com

±ê׼ЭÒé¹âÄ £¿é²úÆ·

¼æÈÝЭÒé¹âÄ £¿é

ÆäËüÖÖÀà¹âÆ÷¼þ

¼¼ÊõÖ§³Ö

ÍøÕ¾µØͼ
ÓÑÇéÁ´½Ó£ºÃ×ÀÖ  ±¦ÂíÓéÀÖÔÚÏßµç×ÓÓÎÏ·  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  XBETÐÇͶÓéÀÖ  ÓÀÓ¯»á  ÓÀÀû¼¯ÍÅ3044»¶Ó­¹âÁÙ  Ç§ÒÚ¹ú¼ÊÓÎÏ·µÇ¼  ÓÀÀû¼¯ÍÅ3044»¶Ó­¹âÁÙ  asiagame  w66ÀûÀ´¹ú¼Ê  ºÀÀû777  BC´û  ×ðÁú¿­Ê±ÈËÉú¾ÍÊDz«  Å·²©abg  Áú8¹ú¼Ê