ÌØÕ÷£º
¡ñ Low Insertion Loss and Wide pass band
¡ñ High Channel Isolation
¡ñ High Stability and reliability
Ó¦Óãº
¡ñ Channel Add/Drop
¡ñ DWDM Network
¡ñ Wavelength Routing
¡ñ Fiber Optical Amplifier
Parameters£º
Specification£º |
||||||||||
Parameters |
Unit |
4 Channel |
8 Channel |
16 Channel |
||||||
Mux |
Demux |
Mux |
Demux |
Mux |
Demux |
|||||
Channel Wavelength |
nm |
ITU 100GHz Grid |
||||||||
Center wavelength Accuracy |
nm |
NA |
||||||||
Channel Spacing |
nm |
100 |
||||||||
Channel Passband (@-0.5dB bandwidth |
nm |
>0.22 |
||||||||
Insertion Loss |
dB |
≤1.6 |
≤2.8 |
≤4.5 |
||||||
Channel Uniformity |
dB |
≤0.6 |
≤1.0 |
≤1.5 |
||||||
Channel Ripple |
dB |
0.3 |
||||||||
Isolation |
Adjacent |
dB |
N/A |
>25 |
N/A |
>25 |
N/A |
>25 |
||
Non-adjacent |
dB |
N/A |
>40 |
N/A |
>40 |
N/A |
>40 |
|||
Insertion Loss Temperature Sensitivity |
dB/¡æ |
<0.005 |
||||||||
Wavelength Temperature Shifting |
nm/¡æ |
<0.002 |
||||||||
Polarization Dependent Loss |
dB |
<0.1 |
<0.1 |
<0.15 |
||||||
Polarization Mode Dispersion |
dB |
<0.1 |
||||||||
Directivity |
dB |
>50 |
||||||||
Return Loss |
dB |
>45 |
||||||||
Maximum Power Handling |
mW |
300 |
||||||||
Operating Temperature |
¡æ |
-5~+75 |
||||||||
Storage Temperature |
¡æ |
-40~85 |
||||||||
Package dimension |
mm |
L100 x W80 x H10 |
L142 x W102 x H14.5 |
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.